- Stent koroner Balon koroner Kateter Kawat panduan Sheath perkenalan Aksesori Produk intervensi perifer
- Imunoasay Diagnostik molekuler Hematology Diagnostic POCT Lab Solution
- Produk penyakit jantung Struktural
- Akses vaskular Transduser tekanan darah Sampel darah arteri Aksesori CVC Kateter IV Konektor bebas jarum Injeksi Insulin Pelega nyeri
- Hemodialisis habis pakai Kartrid Hemoperfusion Mesin dialisis
- ECG Monitor pasien Oksimeter
- Cardiological culars Oncology Anti-infeksi Sistem saraf pusat Lainnya
- Staples bedah Endoskopi Sistem Ultrasound endoskopi
- Implan Trauma Implan tulang belakang Sendi buatan Obat olahraga
- Alat pacu dan lead Peralatan
- ELISA CLIA FIA
- Ekstraksi asam kreat Kit PCR & ekstraksi asam brokat PCR Real Time
- Penganalisis trombelastografi Pengelompokan darah Agregasi gelembung
- POCT-FIA Emas koloid Glukosa darah Kolesterol SARS-CoV-2
- NeoECG Monitor Holter Monitor ECG portabel AI-ECG ECG saku
- Monitor pasien Monitor tanda Vital Capnography akhir pasang
- Oksimeter ujung jari Oksimeter genggam Oksimeter pergelangan tangan Oksimeter yang dapat dipakai Monitor kesehatan serbaguna Solusi POCT
- OBS Pelat kompresi pengunci Pelat pengunci Piring konvensional Sistem pelat Mini Sekrup Produk paten cincin tempurung lutut Pin logam Sistem Kabel
- Sistem fiksasi Internal Sistem pelat laminoplasti Kiroplasti Percutaneous Kandang Fusi Sistem fiksasi serviks
- Sistem pinggul Sistem lutut
- Jangkar jahitan Kancing jahit
Diagram dan parameter teknis:

Specifications & models:
| Specification &model | Diameter luar distal | Diameter luar proximal | Panjang efektif | Diameter dalam lumen |
| LPMC1826150 | 1,8 F | 2,6f | 150cm | 0.016 ″ |
| LPMC1826130 | 1,8 F | 2,6f | 130cm | 0.016 ″ |
| LPMC1923150 | 1,9f | 2,3f | 150cm | 0.016 ″ |
| LPMC1923130 | 1,9f | 2,3f | 130cm | 0.016 ″ |
Spesifikasi umum, disarankan untuk penyimpanan.
Fitur:

Skenario aplikasi:

Tindakan:
Before removing the micro-catheter from the coil, the coil needs to be flushed with heparin saline through the end of the coil to moisten the hydrophilic coating on the surface of the micro-catheter, in order to avoid abrasion of the catheter surface during the withdrawal process
Before the micro-catheter is delivered into the body, a syringe should be used to inject heparin saline into the lumen through the catheter hub to evacuate the air in the lumen and to avoid thrombosis in the lumen
Kawat panduan dan kateter mikro harus dimasukkan secara keseluruhan melalui RHV dan ke dalam kateter pemandu
Kateter mikro harus diputar cukup dan maju secara pelan selama operasi. Ketika perlawanan ditemukan dan tidak mungkin untuk dimuka, coba putar mikro-kateter dengan benar, jangan dorong 17 dan berlebihan-memutar
Terima kasih atas perhatian Anda pada Lepu medis!
Kirimkan Email atau pertanyaan Anda atau gunakan data kontak kami. Kami akan dengan senang hati menjawab Anda Pertanyaan.